Skip to main engineering content
SIPHNET

SIPHONET ENGINEERING

Global Roof Drainage & Hydraulic Studio

Look up global rainfall intensity (API), size gravity drainage under international standards, or upload CAD drawings.

STEP 1 · RAINFALL API & PEAK RUNOFF

Global Rainfall Lookup & Runoff Calculator

Fetch live global weather & IDF storm intensity via Open-Meteo API or enter manually.

Q = r · (A_roof + 0.5·A_wall) · C · R_f

+50% added per EN 12056-3

Effective Catchment A_eff

12,000 m²

Peak Design Runoff Q

600 L/s

Volumetric Flow

2,160 m³/h

9,510.19 GPM

Intensity Equivalent

180 mm/h

≈ 500 L/(s·ha)

Traditional Gravity Drainage Design Parameters

Gravity Roof Outlets

58 × DN110

10.34 L/s per outlet

Vertical Downpipes (Stacks)

9 × DN200

66.67 L/s per stack

Horizontal Collector (Manning)

1 × DN630

Flow Velocity: 3.48 m/s · 65% full

Self-cleansing velocity OK
Hydraulic Losses & Ceiling Drop
Friction Head Loss (h_f):0.644 m
Local Fitting Loss (h_m):2.719 m
Total Head Loss (Σh):3.363 m
Reynolds Re / Darcy f:2,432,277 / 0.0122

Slope Ceiling Space Consumed (ΔZ = L × i): 600 mm

Engineering Comparison: Traditional Gravity vs. Siphonet Siphonic

ParameterTraditional GravitySiphonet Siphonic
Roof Outlets58 × DN11014 × SRO-110 (−76%)
Vertical Downpipes9 × DN2002 × DN200 (−78%)
Horizontal Collector DN1 × DN630DN200 (PE100 Full-Bore)
Slope & Ceiling Clearance1.0% · −600 mm drop0.0% Horizontal · +600 mm saved