On a large factory roof, every conventional gravity downpipe is a commitment: a vertical pipe through the structure, a below-ground connection to a drainage network, and a roof that must be shaped to feed it. Siphonic roof drainage takes a different approach. By running the pipework full-bore, it can consolidate many downpipes into a few, and it frees the building from the sloping pipework that gravity systems depend on.
The problem with conventional roof drainage
Gravity roof drainage relies on partially filled pipes. Water flows downhill under its own weight, so horizontal pipes need a continuous gradient and each outlet needs its own route to the ground. On a mega-span industrial roof, this has three consequences:
- Many downpipes. Capacity per pipe is limited, so large catchments need many vertical drops, often running through production halls, storage areas and façades.
- Sloping pipework. Gradients consume ceiling height and complicate coordination with structure, services and cranes.
- Extensive underground works. Each downpipe typically ends in a below-ground connection, which adds excavation, pipe-laying and coordination on the ground floor.
For automotive, food and beverage, flooring and logistics facilities, where floor space and layout flexibility matter, this is a significant constraint.
The siphonic principle
A siphonic system is designed to run completely full during heavy rainfall. Specially designed roof outlets prevent air from entering the pipework once the system is primed. Siphonet's published figure for full-bore priming depth is 15 mm. With the pipe running full, the system uses the height of the building to generate a siphon effect that pulls water through the pipework at high velocity.
Because the pipes are full, they do not rely on gravity gradients. Siphonet's published figure for the horizontal collector slope is 0%, so collector pipes can run level beneath the roof. Smaller-diameter pipes carry the flow, and a single downpipe can serve a much larger catchment area. Siphonet's published flow figures are 200–300 L/s per line on the VinFast and Suntory PepsiCo projects, and 200–250 L/s on Huali.
These systems are designed to the European standard EN 12056-3 for roof drainage, and Siphonet also works with ASME A112.6.9 for siphonic roof drains. Each system is designed individually: hydraulic design and simulation, supported by BIM coordination, are carried out by Siphonet engineers for every project.
Benefits for large factories
Siphonet publishes the following benefits for its siphonic systems. They are claimed results that vary by project, and should be read as "up to" values rather than guarantees:
- Downpipes consolidated by up to 80%, which clears floor area and reduces the number of penetrations through the building.
- No pipe slopes. Collector pipes can run level, which makes coordination with structure and services simpler.
- Capex savings of 20%, and total savings of around 30%, according to Siphonet's published figures.
- Peak storm runoff reduced by up to 50%, which can ease the load on downstream drainage.
Compact pipework also means fewer excavations for underground connections, which matters on large sites with tight construction programmes. The actual result on any building depends on its roof geometry, rainfall design criteria and layout, and is confirmed through engineering design.
Evidence from projects
Siphonet has delivered siphonic roof drainage for industrial and logistics clients across Vietnam:
- VinFast Vung Ang Phase 2, an automotive and heavy industry facility with a 150,000 m² roof.
- Suntory PepsiCo Long An, a food and beverage plant with a 70,000 m² roof.
- Huali Flooring, Thai Nguyen, a flooring manufacturing facility with an 80,000 m² roof.
One client testimonial reports that 76% of internal downpipes were eliminated on a 42,000 m² roof. Results such as this are specific to the building concerned and its design, but they show the scale of consolidation that siphonic design can achieve on real factory roofs.
Components that make it work
A siphonic system depends on the whole assembly performing together: SS316 or SS304 stainless steel roof outlets, including SS316L anti-vortex outlets; electrofusion-welded PE100 HDPE piping; and anti-vibration rail systems to support the pipework. Hydraulic simulation and testing, together with BIM, help ensure that the system is coordinated with the building before installation begins.
Conclusion
For large factories, siphonic roof drainage replaces a forest of downpipes and sloping pipes with a compact, full-bore system. Siphonet's published figures point to up to 80% fewer downpipes, along with savings in capital cost and a reduction in peak runoff. The result for your building depends on its design, and that is where early engineering involvement counts.
If you are planning a mega-span roof, a factory or a logistics park, talk to the Siphonet engineering team early in the design process.
SIPHONET JOINT STOCK COMPANY N07-B1 Dich Vong, Cau Giay, Hanoi, Vietnam Phone: +84 913 381 683 Email: siphonet@gmail.com Web: siphonet.com